welcome to here

Site map

Professional Communication Cable Producer. Patch Cord, Lan Cable, Cat5e, Cat6, Cat6a, Cat7, Cat7a, Cat8

+86-15016934098

Home   |   Products   |   Outdoor cable   |  

Taifeng High quality Shield lan cable pass fluke test

这里可以自定义设置
Taifeng High quality Shield lan cable pass fluke test
B站不支持收货地址
B站不支持库存规格
Place of Origin:
Guangdong, China
Color:
Black /white/or customer need
Brand Name:
Taifeng or OEM
Model Number:
S6--4P-FTP-001
Product Name:
FTP cat6 Lan cable
Number of Conductor:
8
Supply Ability:
150000box/month
Port:
Shenzhen , China
Payment terms:
T/T
Trade terms:
FOB,CNF,CIF,EXW
参数暂无数据
多属性暂无数据
B站不支持优惠卷

Add success, do you want to check your shopping cart?

暂无分享
B站不支持产品保障
该产品后台详情无内容

Product Description

Taifeng provides CAT6 Data Copper Cable using patent (ZL 20152 0298848.7) production to meet the highest performance requirements of Gigabit Ethernet on CAT6 cables at its test frequency of up to 350MHZ.
In practical applications, construction and installation and connection points increasing will pose influence on transmission signals, if combination of Taifeng end-to-end product series will have more perfect performance to ensure effective Gigabit Ethernet applications. For CAT6 Copper Cable of Taifeng, their performance exceeds the standard requirements, with test frequency up to 350MHZ, superior to 250MHZ required for T2A568B and IEC11801

这里可以自定义设置

Product Information

◆ Conductor Material: Bare cooper

◆ Insulation: HDPE /PE

◆ Jacket: PVC(CM/CMR/CMP)LSOH,PE for outdoor cable

◆ Length:100/305/1000M or customer request

◆ Packaging Details:

1.Pull out box 305m/pull out box, 2boxes/outer carton.  
2.Wooden/plastic reel.  
3.AS per customer request.

Product Parameters

Customer: DELTA
PRODUCT SPECIFICATION:#23 1/0.57Bx4P UTP6 LAN CABLE 
Cross SectionPerfomance
ELECTRICAL CHARACTERISTICS(20℃)
MAX.CONDUCTOR DC RESISTANCE ( /KM) #23:89
MIN.INSULATION RESISTANCE ( /KM)  PE:100M
DIELECTRIC STRENGTH  AC-500V/1 MIN NO BREAKDOWN
D-C RESISTANCE UNBALANCE:MAX 2%
PAIR-TO-GROUND CAPACITANCE UNBALANCE:MAX. 330PF/100M
INPUT IMPEDANCE: 4-100MHz 100+/-15ohm
100-250MHz 100+/-22ohm
MEAN CHARATRERISTIC IMPEDANCE@100MHZ: 100+/-5 OHMS
MarkingNOMINAL VELOCITY OF PROPAGETION(NVP) 68+/-2%
Jacket Marking: /PROPAGATION DELAY @ 100MHZ ≧537.6 ns/100M
ConstructionPROPAGATION DELAY SKEW:MAX. ≧45ns/100M
Conductor Bare CopperFREQUENCY RANGE MINIMUN REQUIREMENTS(EQUATIONS)
4 Twisted Pair8CINSERTION LOSS 4-250MHZ IEC61156-6:EQUATION(2).CONSTANT VALUES SEE TABLE 4 CAT.6
AWG23
Construction (MM)1/0.57RETURN LOSS 4-250MHZ IEC61156-6:SEE TABLE 10
Stranded Dia.(MM)/INPUT IMPEDANCE 4-250MHZ IEC61156-6:SEE TABLE 10
InsulationPENEXT 4-250MHZ IEC61156-6:EQUATION(6),CONSTANT VALUES SEE TABLE 6 CAT.6
Nom.Thickness (MM)0.225
Insulation Dia.( ±0.05)1PS NEXT 4-250MHZ IEC61156-6:EQUATION(5),CONSTANT VALUES SEE TABLE 6 CAT.6
SeparatorPE Cross
Shield/Braid/
Overlap(%)/ELFEXT 4-250MHZ IEC61156-6:EQUATION(7),CONSTANT VALUES SEE TABLE 6 CAT.6
Darin wire/
JacketPVC
Nom.Thickness (MM)0.6PS ELFEXT 4-250MHZ IEC61156-6:EQUATION(7),CONSTANT VALUES SEE TABLE 6 CAT.6
Outer Dia.( ±0.2MM)6.5
ColorPhysical PropertiesInsulationTens strength(before aging)Kgf/mm2>1.68
Insulation
Tens strength(after aging)Kgf/mm2
Cores:Pairs
Elongation(before aging)%>300%
P1:Blue & WhiteP2:Orange & WhiteElongation(after aging)%
P3:Green & WhiteP4:Brown & WhiteJacketTens strength(before aging)Kgf/mm2>1.41
Jacket
Tens strength(after aging)Kgf/mm2


Elongation(before aging)%>100%


Elongation(after aging)%


Conductor ResistanceΩ/km<93.8


20℃


Insulation shrinkback
121℃x1hr
benging test
Insulation cold bend
-20℃x4hr
MAX.pulling    
Jacket cold bend
-20℃x4hr
这里可以自定义设置
这里可以自定义设置
Chat Online 编辑模式下无法使用
Chat Online inputting...